CONTACT US

This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Jakarta Office : 021-45850618


   Surabaya Office : 031-8421264 

 
Fluke 438 Series II Power Quality and Motor Analyzer

Features

Quickly and easily discover electrical and mechanical performance of electric motors, and evaluate power quality with a single test tool

The Fluke 438-II Power Quality and Motor Analyzer adds key mechanical measurement capabilities for electric motors to the advanced power quality analysis functions of the Fluke 435 Series II Power Quality Analyzers. Quickly and easily measure and analyze key electrical and mechanical performance parameters such as power, harmonics, unbalance, motor speed, torque and mechanical power without the need of mechanical sensors. Fluke 434-II, 435-II and 437-II Power Quality Analyzer users can add motor analysis capabilities to their existing units with the Fluke-438-II/MA Motor Analyzer upgrade kit. 

The ideal portable motor analysis test tool, the 438-II can help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems, while giving technicians the mechanical and electrical information they need to effectively evaluate motor performance.

  • Measure key parameters on direct-on-line motors including torque, RPM, mechanical power and motor efficiency
  • Perform dynamic motor analysis by plotting of motor derating factor against load according to NEMA/IEC guidelines
  • Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you're ready to go
  • Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency
  • Identify power quality issues such as dips, swells, transients, harmonics and unbalance
  • PowerWave data technology captures fast RMS data, and shows half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
  • Waveform capture function captures 100/120 cycles (50/60 Hz) of each event detected event, in all modes, without set-up
  • Automatic transient mode captures waveform data at 200 kS/s on all phases simultaneously up to 6 kV
  • Fluke Connect® compatible* – view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software
  • Safety rated for industrial applications 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream

 

 

Specs

Motor measurement

  Range Resolution Accuracy Default limit
Mechanical motor

Power
0.7 kW to 746 kW

1 hp to 1000 hp
0.1 kW

0.1 hp
±3%1

±3%1
100% = rated power

100% = rated power
Torque 0 Nm to 10 000 Nm

0 lb ft to 10 000 lb ft
0.1 Nm

0.1 lb ft
±5%1

±5%1
100% = rated torque

100% = rated torque
rpm 0 rpm to 3600 rpm 1 rpm ±3%1 100% = rated rpm
Efficiency 0% to 100% 0.10% ±3%1 NA
Unbalance (NEMA) 0% to 100% 0.10% ±0.15% 5%
Harmonics Voltage
Factor (NEMA)
0 to 0.20 0.1 ±1.5% 0.15
Unbalance Derating
Factor
0.7 to 1.0 0.1 indicative NA
Harmonics Derating
Factor
0.7 to 1.0 0.1 indicative NA
Total NEMA Derating
Factor
0.5 to 1.0 0.1 indicative NA
Notes: Supports motor design types NEMA A, B, C, D & E and IEC type H and N.
Rated torque is calculated from rated power and rated speed.
Update rate of Motor Measurements is 1x per second.
Default Trend duration is 1 week.

1Add 5% error when selecting Motor design type Other
Specification valid for Motor Power > 30% of rated power
Specification valid at stable operating temperature. Run the motor for at least 1 hour at full load
(2-3 hours if the motor is 50 HP or higher) to obtain stable temperature

Product Specifications

Volt Model Measurement Range Resolution Accuracy
Vrms (AC + DC) 1 V to 1000 V phase to neutral 0.01 V ±0.1% of nominal voltage1
Vpk 1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.8 0.01 ±5%
Vrms½   0.1 V ±0.2% of nominal voltage
Vfund   0.1 V ±0.1% of nominal voltage

Amps (accuracy excluding clamp accuracy)

Amps (AC + DC) i430-Flex 1x  5 A to 6000 A 1 A ±0.5% ±5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
1mV/A 1x 5 A to 2000 A 1A ±0.5% ±5 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
Apk i430-Flex 8400 Apk 1 Arms ±5%
1mV/A 5500 Apk 1 Arms ±5%
A Crest Factor (CF) 1 to 10 0.01 ±5%
Amps½ i430-Flex 1x 5 A to 6000 A 1 A ±1% ±10 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±1% ±10 counts
1mV/A 1x 5 A to 2000 A 1 A ±1% ±10 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±1% ±10 counts
Afund i430-Flex 1x 5 A to 6000 A 1 A ±0.5% ±5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
1mV/A 1x 5 A to 2000 A 1 A ±0.5% ±5 counts
1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts

Hz

Fluke 434 @ 50 Hz Nominal 42.50 Hz to 57.50 Hz 0.01 Hz ±0.01 Hz
Fluke 434 @ 60 Hz Nominal 51.00 Hz to 69.00 Hz 0.01 Hz ±0.01 Hz

Power

Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ±1% ±10 counts
1 mV/A max 2000 MW 0.1 W to 1 MW ±1% ±10 counts
Power Factor (Cos j/DPF) 0 to 1 0.001 ±0.1% @ nominal load conditions

Energy

kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts
Energy Loss i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts Excluding line resistance accuracy

Harmonics

Harmonic Order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-Harmonic Order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
Absolute 0.0 to 1000 V 0.1 V ±5%1
THD 0.0% to 100% 0.1% ±2.5%
Amps % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
Absolute 0.0 to 600 A 0.1 A ±5% ±5 counts
THD 0.0% to 100% 0.1% ±2.5%
Watts % f or r 0.0% to 100% 0.1% ±n x 2%
Absolute Depends on clamp scaling and V nominal ±5% ±n x 2% ±10 counts
THD 0.0% to 100% 0.1% ±5%
Phase Angle -360° to +0° ±n x 1°

Flicker

Plt, Pst, Pst (1 min) Pinst 0.00 to 20.00 0.01 ±5%

Unbalance

Volts % 0.0% to 20.0% 0.1% ±0.1%
Amps % 0.0% to 20.0% 0.1% ±1%

Mains Signaling

Threshold Levels Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling Frequency 60 Hz to 3000 Hz 0.1 Hz  
Relative V % 0% to 100% 0.10% ±0.4%
Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ±5% of nominal voltage

General Specifications

Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory 8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32 GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-Time Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture

Environmental

Operating Temperature 0°C ~ +40°C; +40°C ~ +50°C excl. battery
Storage Temperature -20°C ~ +60°C
Humidity +10°C ~ +30°C: 95% RH non-condensing
+30°C ~ +40°C: 75% RH non-condensing
+40°C ~ +50°C: 45% RH non-condensing
Maximum Operating Altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery

1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if < 1% of nominal voltage
2. 50Hz/60Hz nominal frequency according to IEC 61000-4-30
3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode
4. For nominal voltage 50 V to 500 V

 

Models

Model Name Consist of Price
FLUKE 438 II
  • Fluke 438-II Power Quality and Motor Analyzer
  • Test lead set
  • i430 Thin flexible current probes (4)
  • Battery
  • Power adapter
  • Combination WiFi/SD card
  • Soft carry case
  • CD Rom with PowerLog 430-II software and user documentation
Get a Quote
FLUKE 438-II BASIC
  • Fluke 438-II Power Quality and Motor Analyzer
  • Test lead set
  • Battery
  • Power adapter
  • 8GB SD card
  • Soft carry case
  • CD Rom with PowerLog 430-II software and user documentation
Get a Quote
FLUKE 438-II/INTL
  • Fluke 438-II Power Quality and Motor Analyzer
  • Test lead set
  • i430 Thin flexible current probes (4)
  • Battery
  • Power adapter
  • 8GB SD card
  • Soft carry case
  • CD Rom with PowerLog 430-II software and user documentation
Get a Quote
FLUKE 438-II/MA Firmware upgrade package to add motor analysis capabilties to existing Fluke 434, 435 and 437 Series II Power Quality Analyzers Get a Quote

Software

Power Quality Software Downloads

To ensure your product has the latest software release that include new features, click on the appropriate link below and follow the download instructions.

Fluke 430 Series II Three-Phase Energy and Power Quality Analyzers

Download

Last updated

Firmware Update V05.00 (.exe) »
The application requires a COM port number to be selected, this information can be found in Windows device manager device list. The application provides step by step instructions. Important: Please read HELP text in upgrader before proceeding.

06/2016

Firmware Update V05.00 Release Notes (.pdf) »
Complete details of the benefits of updating to V05.00. These notes are important to ensure save preservation of existing data, consult the short guide on data backup if in doubt.

06/2016

PowerLog430-II Application Software V5.2 for Fluke 430 Series II (.exe) »
PowerLog Application software for Fluke Power Quality analyzers 430-II, only.

06/2016

PowerLog430-II V5.2 Release Information (.pdf) »
Complete details of new features and bug fixes – it is important to read these notes.

06/2016

Backing Up and Copying Data from the Fluke 430 (.pdf) »
A short guide on backing up the important data on your instrument. Also includes guidance on data archiving.

9/2012

Fluke 430 Series II USB driver (.zip) »
The Fluke 430 Series II USB driver will install automatically under normal circumstances. This file is for manual installation when Internet access is not available.

 