Additel 681 Digital Pressure Calibrator

Features

At Additel, fully temperature compensated accuracy means every sensor is pressure tested at several environmental temperatures from -10°C to 50°C. With this test data individual coefficients are generated and stored in the gauge characterizing its performance over the full temperature compensated range. And now the ADT681IS comes with an IP67 rating meaning it is dust resistant and water proof, submerible in 1 meter of water.

Application :

  • Precision pressure measurement
  • Field gauge calibration
  • Pressure safety valve (PSV) testing
  • Pressure regulator testing

Specs

 

 • Model

  ADT681: Regular gauge
  ADT681IS: ATEX and CSA US certified intrinsically safe

• Accuracy
  681(IS)-02: 0.02% of full scale
  681(IS)-05: 0.05% of full scale
  681(IS)-10: 0.1% of full scale
  681(IS)-20: 0.2% of full scale     
   
681(IS)-RD: 0% to 20% of Range: 0.02% of full scale; 
                    20% to 110% of Range: 0.1% of reading; 
                    Vacuum: 0.25% of full scale[1][2]
  [1] FS= - 14.5 psi
  [2] Applicable ADT681-RD-CPX

  (For detailed accuracy, please see pressure range table)

• Gauge Types
  Gauge pressure
  Compound pressure
  Absolute pressure
  Differential pressure

• Fan-shaped Graph Scale
  Similar to analog dials, including pressure swing, 
  % indication with fan-shaped graph scale for visual reference, low/high alarm.

• Display
  Description: 5 full digit FSTN LCD
  Display rate: 3 readings per second (Default setting).
  Adjustable from 10 readings per second to 1 reading every ten seconds
  Numeral display height: 16.5mm (0.65")

• Pressure Units
  Pa, kPa, MPa, psi, bar, mbar, kgf/cm2, inH2O 4°C mmH2O 4°C, inHg 0°C, mmHg 0°C

• Environmental
  Compensated Temperature: 14°F to 122°F (-10°C to 50°C)
  Operating Temperature*: 14°F to 122°F(-10°C to 50°C)
  Storage Temperature: -4°F to 158°F (-20°C to 70°C)
  Humidity: <95%

• Pressure Port
  1/4NPT male, 1/4BSP male, M20×1.5 male (≤15,000 PSI)
  1/4HP female or 1/4HP male(≥15,000 PSI)
  *1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B 
  *1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A
  0.236 inch (Ø6 mm) test hose (for differential pressure)
  Other connections available per request

• Power
  Battery: One 9V alkaline battery (included)
  Battery life: 300 hours (10 readings/s), 600 hours (3 reading/s), or 6000 hours (1 reading/10s)
  Power auto-off: 60 minutes power auto-off. Auto-off may be disable
  External power: 110/220V external power adapter (optional)
  *(Do not use the external power adapter in a hazardous atmosphere)

• Enclosure
  Case material: Aluminum alloy
  Wetted parts: 316L SS
  Dimension: 
    Ø110mm X 35mm depth X 176mm height
    (panel mount gauge: Ø140mm X 86mm depth)
  Weight: 0.6kg

• Compliance
  Protection Level: IP67(available for 681IS GP15-40K)
  Vibration: 5g (20-2000 Hz)
  Shock Resistance: 100g/11ms

• Data Logging 
  Data storage: 21,843 records (each record includes date, time, pressure and temperature)
  Rate: user-selectable from 1 to 99,999 second intervals

• Intrinsic Safety and European Compliance 
  CE marked
  ATEX and CSA US certified intrinsically safe (ADT681IS)
  *(Rubber boot for ADT681 is not ATEX and CSA certified)

• Communication: 
  RS232     *(Do not use the RS-232 connector in a hazardous atmosphere)

• Pressure Range

 

Gauge Pressure [1]

P/N

Pressure Range

Media [2]

Accuracy(%FS)

Burst
Pressure

(psi)

(bar)

V15

-15

-1.0

G

0.02 (0.05,0.1, 0.2)

GP2

2

0.16

G

0.05 (0.1, 0.2)

GP5

5

0.35

G

0.05 (0.1, 0.2)

GP10

10

0.7

G

0.02 (0.05, 0.1, 0.2)

GP15

15

1.0

G, L[3]

0.02 (0.05, 0.1, 0.2)

GP30

30

2.0

G, L[3]

0.02 (0.05, 0.1, 0.2)

GP50

50

3.5

G, L

0.02 (0.05, 0.1, 0.2)

GP100

100

7.0

G, L

0.02 (0.05, 0.1, 0.2)

GP300

300

20

G, L

0.02 (0.05, 0.1, 0.2)

GP500

500

35

G, L

0.02 (0.05, 0.1, 0.2)

GP600

600

40

G, L

0.02 (0.05, 0.1, 0.2)

GP1K

1,000

70

G, L

0.02 (0.05, 0.1, 0.2)

GP2K

2,000

140

G, L

0.02 (0.05, 0.1, 0.2)

GP3K

3,000

200

G, L

0.02 (0.05, 0.1, 0.2)

GP5K

5,000

350

G, L

0.02 (0.05, 0.1, 0.2)

GP10K

10,000

700

G, L

0.02 (0.05, 0.1, 0.2)

GP15K

15,000

1,000

G, L

0.05 (0.1,0.2)

GP20K

20,000

1,400

G, L

0.05 (0.1,0.2)

1.5×

GP25K

25,000

1,600

G, L

0.1 (0.2)

1.5×

GP30K

30,000

2,000

G, L

0.1 (0.2)

1.5×

GP36K

36,000

2,500

G, L

0.1 (0.2)

1.5×

GP40K

40,000

2,800

G, L

0.1 (0.2)

1.1×

 

Compound Pressure

P/N

Pressure Range

Media

Accuracy(%FS)

Burst
Pressure

(psi)

(bar)

CP2

±2

±0.16

G

0.05(0.1,0.2)

CP5

±5

±0.35

G

0.02 (0.05,0.1,0.2)

CP10

±10

±0.7

G

0.02 (0.05,0.1,0.2)

CP15

±15

±1

G

0.02(0.05,0.1,0.2)

CP30

-15 to 30

-1 to 2

G

0.02(0.05,0.1,0.2)

CP100

﹣15 to 100

﹣1 to 7

G, L

0.02(0.05,0.1,0.2)

CP300

﹣15 to 300

﹣1 to 20

G, L

0.02(0.05,0.1,0.2)

 

Absolute Pressure

P/N

Pressure Range

Media

Accuracy(%FS)

Burst
Pressure

(psi)

(bar)

AP5

5

0.35

G

0.1 (0.2)

AP10

10

0.7

G

0.1 (0.2)

AP15

15

1.0

G

0.1 (0.2)

AP30

30

2.0

G

0.1 (0.2)

AP50

50

3.5

G

0.1 (0.2)

AP100

100

7.0

G, L

0.05 (0.1,0.2)

AP300

300

20

G, L

0.05 (0.1,0.2)

AP500

500

35

G, L

0.05 (0.1,0.2)

AP1K

1,000

70

G, L

0.05 (0.1,0.2)

AP3K

3,000

200

G, L

0.05 (0.1,0.2)

AP5K

5,000

350

G, L

0.05 (0.1,0.2)

 

Differential Pressure

P/N Pressure Range Media Accuracy
(%FS)[4]
Burst
Pressure
Static 
Pressure
Range
(inH2O) (mbar)
DP1 ±1 ±2.5 G 0.05[5] 100× ±10 psi
DP2 ±2 ±5.0 G 0.05[5] 100× ±10 psi
DP5 ±5 ±10 G 0.05[5] 50× ±10 psi
DP10 ±10 ±25 G 0.05[5] 20× ±10 psi
DP20 ±20 ±50 G 0.05 20× ±10 psi
DP30 ±30 ±75 G 0.05 15× ±10 psi
DP50 ±50 ±160 G 0.05 ±10 psi
DP150 ±150 ±350 G 0.02 (0.05) 50 psi
DP300 ±300 ±700 G 0.02 (0.05) 50 psi

*Note: [1]. Sealed gauge pressure for above 1000 psi
[2]. G=Gas, L=Liquid (please specify media type when place order)
[3]. 0.02% FS for gas media only
[4] FS specification applies to the span of the range. Accuracy includes one year stability.
[5] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS
calibration accuracy combined with 0.05%FS one year stability.

Models

ADT681 - 02 - GP300 - PSI - N - PB -DL

Note :

ADT 680 - model ADT681 or ADT681IS

02 - accuracy
02 = % of full scale
05 = 0.05% of full scale
10 = 0.1% of full scale
20 = 0.2% of full scale
25 = 0.25% of full scale
RD = 0.1% of reading

GP300 - pressure range P/N
see pressure range table

PSI - range type
PSI = range by psi
BAR = range by bar
H2O = range by H2O

N - pressure port type
N = 1/4NPT male
N2 = 1/2NPT male
B = 1/4BSP male
B2 = 1/2BSP male
M = M20X1.5 male
AF = Autoclave F-250-C female
AM = Autoclave M-250-C male

PB - Panel mount with back pressure port

DL - data loggig

Accessories included

  • 9V battery - 1pc
  • Manual
  • NIST traceable calibration certificate
  • Rubbet boot (except panel mount and 681IS)


Accessories

Model Name Description Price
9812 110V/220V external power adapter (DC 9V) for ADT681  
9502 Additel/Log II real time data logging and graphical software for ADT681 and 672  
9506 Additel/PCal pressure calibration software  
9050 USB to RS232 (DB9/M) Adapter  
9900-681 Carrying case for one 681 digital pressure gauge  