Fluke 115 Field Service Technicians Multimeter

Features

Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.

 

Specs

Specifications

Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
   400 hours typical, without backlight

 

Accuracy Specifications

DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.00 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 µF / 0.01 µF
Range/Resolution:  100.0 µF / 0.1 µF
Range/Resolution:  9999 µF / 1 µF
Range/Resolution:  100 µF to 1000 µF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 µF
Accuracy:  5% + 20%
Lo-Z Capacitance
Range:  1 nF to 500 µF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
   20 A overload for 30-seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
   20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.9 Hz / 0.01 Hz
Range/Resolution:  9.999 kHz / 0.001 kHz
Range/Resolution:  50 kHz / 0.01 kHz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage

 

Mechanical & General Specifications

Size
 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
 550 g

Models

Model Name Consist of Price
FLUKE 115
  • Fluke 115
  • Holster
  • Installed 9V battery
  • 4 mm silicone test lead set
  • User manual