Fluke 116 HVAC Multimeter with Temperature and Microamps

Features

Compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors. 

 

Specs

Specifications

Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
   400 hours typical, without backlight

 

Accuracy Specifications

DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  1.5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:  -40 °C to 400 °C / 0.1 °C
Accuracy:  1% + 102
Range/Resolution:  -40 °F to 752 °F / 0.2 °F
Accuracy:  1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
DC μamps
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

 

Mechanical & General Specifications

Size
   167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
   550 g

Models

Model Name Consist of Price
FLUKE 116
  • Fluke 116
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9V battery
  • 4 mm silicone test lead set
  • User manual
 

 

Brochure">