Fluke TiX520 Infrared Camera

Features

Your view of infrared technology is about to change 180°. The answer is right before your eyes, even when your target isn't.

  • Easily navigate over, under and around objects with the 180° articulating lens and see the image before you capture it
  • Capture images with the only 5.7 inch responsive touchscreen LCD with on-camera analytics for in-field image analysis¹
  • Save time with post-capture image processing - edit emissivity, background temperature, transmissivity, palettes, color alarms, IR-Fusion and enable/disable markers all on cameras

 

Specs

Key Features

IFOV with standard lens (spatial resolution) 1.31 mRad
Detector resolution 320 x 240 (76,800 pixels)
Field of view 24 °H x 17 °V
Minimum focus distance 15 cm (approx. 6 in)
IFOV with optional telephoto lens 0.65 mRad
Field of view 12 °H x 9 °V
Minimum focus distance 45 cm (approx. 18 in)
IFOV with optional wide-angle lens 2.62 mRad
Field of view 46 °H x 34 °V
Minimum focus distance 15 cm (approx. 6 in)
SuperResolution* In software
Image sharpening -
LaserSharp® Auto Focus Yes, for consistently in-focus images. Every. Single. Time.
Laser distance meter Yes, calculates distance to the target for precisely focused images and displays distance on screen
Advanced manual focus Yes
Streaming video (remote display) Via USB or WiFi
Touchscreen display (capacitive) 14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Wireless connectivity Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)
Fluke Connect™ app compatible Yes (where available)
Fluke Connect™ tool compatible Yes (where available). Connects wireless to select Fluke Connect™ enabled tools. Five simultaneous connections supported.
IR-Fusion® technology Yes
AutoBlend™ mode Yes
Picture-In-Picture (PIP) Yes
Continuous AutoBlend™ -
Rugged, ergonomic design for one-handed use Rotatable (articulating lens) >180 degrees
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C target temp (50 mK)
Filter mode (NETD improvement) ≤ 0.04 °C at 30 °C target temp (40 mK)
Level and span Smooth auto and manual scaling
Touchscreen adjustable level / span Yes. Span and level can be easy and quickly set by simply touching the screen.
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
Built-in digital camera (visible light) 5 megapixel industrial performance
Frame rate 60 Hz or 9 Hz versions
Laser pointer Yes
LED light (torch) Yes
Digital zoom 2x, 4x

Data Storage and Image Capture

Extensive memory options Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
Image capture, review, save mechanism One-handed image capture, review, and save capability
Post-capture image editing (on camera) Yes. Conduct on camera analysis for in-field results.
Advanced text annotation Yes. Including standard shortcuts as well as user programmable options.
File formats Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Memory review Thumbnail view navigation and review selection
Software SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App - full analysis and reporting software
Export file formats with SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided
IR-PhotoNotes™ Yes
Text annotation Yes
Video recording Standard and radiometric
File formats video Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Remote control and operation (for special and advanced applications) -
Auto capture (temperature and interval) Yes

Battery

Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery life Three hours continuous use per battery pack
Battery charge time 2.5 hours to full charge
Battery charging system Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power saving User selectable sleep and power off modes

Temperature Measurement

Temperature measurement range (not calibrated below -10 °C) -20 °C to +850 °C (-4 °F to +1562 °F)
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes

Color Palettes

Standard palettes 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ palettes 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra

General Specifications

Color alarms (temperature alarms) High-temperature and low-temperature
Infrared spectral band 7.5 μm to 14 μm (long wave)
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Center-point temperature measurement Yes
Spot temperature Hot and cold spot markers
User-definable spot markers 3 user-definable spot markers
Center box Expandable-contractible measurement box with MIN-MAX-AVG temp
Safety IEC 61010-1: Overvoltage Category II, Pollution degree 2
Electromagnetic compatibility IEC 61326-1: Basic EM Environment
CISPR11, Group 1, Class A
Australian RCM IEC/61326-1
US FCC CFR 47, Part 15 Subpart B
Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 1 meter (3.4 feet) drop with standard lens
Size (H x W x L) 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in)
Weight (battery included) 1.5 kg (3.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

* Coming soon via firmware upgrade

Models

Model Name Consist of Price
FLUKE TiX520
  • Thermal imager with standard infrared lens
  • Ac power supply and battery pack charger (including universal ac adapters)
  • Two, rugged lithium ion smart battery packs
  • USB cable
  • HDMI video cable
  • Bluetooth headset (where available)
  • Rugged, hard carrying case
  • Adjustable neck and hand strap
  • Flash drive with SmartView® Software and user manuals
  • Warranty registration card and calibration certificate

 